當前位置:新聞動態 > 技術支持 > 多欽儀表電磁流量計空管報警可能性原因分析
<< 多欽儀表(上海)有限公司 專注於流量計與服務 >> 使用維護
zaiyibandeguanluyeticedingzhong,liuliangjizhiyoucedingdanxiangdeyeti,ruoyetifangweigaibian,zecedingmeifajinxing。keyicedingshuangxiangzongliuliangdeliuliangjibukeduode,zhengchangqingkuangxiawomenlejiedeyoudianciliuliangjihechaoshengboliuliangji,dianciliuliangjidezhengfanmianliuxiangdounenggougenjushezhijinxing。zaishuipingan裝shi,zongliuliangxuanzeweidangchangtigongbushaobianjie。danshizaichuizhian裝shiyetizhiyouzixiaershangdegenjuliuliangji。dianciliuliangjiduimanguanguidingyange,dangyetitongguoliuliangjishiweidadaomanguanguidingshi,現kongguanjingbao,biaotouxianshiwuzongliuliang。

dianciliuliangjizaiyingyongdeguochengzhongjingchanghuiyudaokongguanjingbaozhuangkuang,suoweidianciliuliangjidekongguanjingbaoshizhijiancecedingyetishifoutianmankongzhiqicedingguan,jiancekongguanjingbaodefashengyuanyin,womenkeyigenjuyongdaoxianjiangzhuanhuaqixinhaoshuruduanzihedi3dianduanlu,cedingdejieguoruguokongguanbianmanguan,zeshuomingdianciliuliangjidezhuanhuaqizhengchangqingkuangxia,chuxianguzhangdeyuanyinjiujianghuishibeiceyetidiandaolvdihuokongguanfazhishezhicuowu。chucizhiwai,ruguodianciliuliangjidedianjichu現lewenti,nameyejianghuihuichu現kongguanjingbaodeqingkuang。
空管報警閥值經常相互配合空管警報應用。空管報警閥值一般設置在500%,空(kong)管(guan)警(jing)報(bao)是(shi)一(yi)個(ge)相(xiang)對(dui)的(de)值(zhi),它(ta)與(yu)滿(man)管(guan)狀(zhuang)態(tai)和(he)介(jie)質(zhi)的(de)電(dian)導(dao)率(lv)常(chang)有(you)直(zhi)接(jie)的(de)關(guan)係(xi),空(kong)管(guan)報(bao)警(jing)閥(fa)值(zhi)將(jiang)尺(chi)寸(cun)將(jiang)決(jue)定(ding)空(kong)管(guan)警(jing)報(bao)的(de)靈(ling)敏(min)度(du),在(zai)確(que)定(ding)空(kong)管(guan)報(bao)警(jing)閥(fa)值(zhi)前(qian),應(ying)當(dang)***先測定是測定的介質(即電導率)和he該gai介jie質zhi在zai滿man管guan狀zhuang態tai下xia的de阻zu值zhi率lv。然ran後hou再zai考kao慮lv液ye體ti掛gua壁bi的de時shi間jian等deng適shi當dang設she置zhi警jing報bao反fan應ying時shi間jian,所suo以yi空kong管guan警jing報bao的de閥fa值zhi應ying當dang是shi一yi個ge可ke調tiao整zheng的de參can數shu。
在實際應用中,將液體處於滿管狀態下的電阻器值定義為100%,即在液體滿管時,用“空管警報閾值”將空管測定值校準到100%。dangguanluzhongyetiyemiandiyucedingdianjishi,xiangduidianzuqijiangzenggao,danggaoyukongguanjingbaoyuzhishiyibiaopanjiangxianshikongguanbaojingxitong。lilunshangkongguanbaojingfazhishezhizai900%當空管時即可以顯示空管警報。空管報警閥值越小,空管警報越靈敏。各根據當場需求設置。電磁流量計出現空管警報時處理辦法:
1、測定液體是否填滿測定管;
2、用導線將轉化器信號接入端子SIG1、SIG2和SIGGDN3點短路,此時如果“空管”提示撤銷,說明轉化器正常情況下,有將會是被測液體電導率底或空管閥值及空管量程設置錯誤;
3、檢查信號線連接是否正確;
4、檢查控製器電極是否正常情況下;
5、使總流量為零,觀察顯示電導比應小於100%;
6、在有電流的情況下,分別測定端子SIG1、SIG2和SIGGDN的電阻器應小於50kΩ。